Filter Design Workspace
One connected view of your filter: geometry, characterization, requirements, and results. Every section links directly to the detailed modeling page.
Engineering estimates only — not safety certification or code compliance. Results must be independently validated by a qualified engineer.
Identity
Name
Core V1 47mm — 2 Layers — 3 Layers
Manufacturer
—
Part number
—
Material
ceramic
Filter type
ceramic
Pore size
0.3 um
Porosity
—
Source
—
Filter Project: Unknown / unavailable(6ab04ab08966a00d941338bf)
Geometry
Nominal diameter
—
Active flow diameter
47 mm
Gross media area
—
Effective transport area
—
Layer count
3
Individual layer thickness
100 µm
Total stack thickness
0.300 mm
Geometry mode
rectangular
Stacked layers increase total thickness and resistance — NOT frontal area. Each layer shares the same nominal/active diameter. Total stack thickness = 3 × 100 µm = 0.300 mm.
Characterization Status
Geometry
Partial
Flow / ΔP
Not characterized
Particulate Retention
TBD
Gas Transport / Diffusion
Not characterized
Structural / Transient
TBD
Scenario Evaluation
Not run
Provenance 0%
Modeling & Analysis
Filter Catalog
Edit filter properties & geometry
Filter Flow / Flux Lab
Measured flow/ΔP, design-point check, GC → flux → sizing
Membrane / Gas Transport
Diffusion, permeability, permeance
Filter Sizing
How many filters needed
Filter Evaluation
Evaluate against a scenario
Compare Filters
Side-by-side transport comparison
Experimental Lab
Fit transport from measured data
Reports
Generate engineering report
Scenarios
Define evaluation scenarios
Design Requirements
No design requirements defined yet. Click "Add Requirements" to specify flow, ΔP, geometry, particulate, transport, and structural targets.
Measured Flow / ΔP Characterization
Enter measured paired flow/pressure-drop data points. When a measured curve exists, it takes precedence over calculated correlations for downstream sizing and evaluation. Reference conditions (standard vs actual) are always explicit — never mixed silently.
Measured Data Points
No measured data points yet. Add at least two for interpolation.
Design-Point Requirement
Reference conditions define the standard/normal flow basis. 0 °C / 1 atm = NTP. 20 °C / 1 atm = STP. Never mix reference conditions silently.
Particulate Retention(0)
No particulate retention data. Add evidence to evaluate retention.
H₂ / Gas Transport(0)
Gas transport is distinct from air-flow resistance. H₂ diffusivity cannot be inferred from air ΔP.
No gas transport data. Add evidence to evaluate H₂/gas transport.
Particulate Loading(0)
No extrapolation outside measured range. No universal loading law is assumed.
No loading data. Add experimental loading curves to evaluate loading margin.
Structural / Transient Evidence(0)
No test evidence = INSUFFICIENT_DATA, not PASS. This is not a finite-element solver.
No structural test evidence. Add test results to evaluate structural qualification.
Evaluate Against Scenario
Scenario calculation complete[Preset] Standard Radiolysis (1 W, G=0.45)
H₂ generation rate
4.6639e-8 mol/s
Final H₂ fraction
0.0821%
Final total pressure
1.0141e+5 Pa
Species routing
Species routing: H₂ supported
H₂ transport evidence
No evidence
Credited H₂ removal
Not evaluated / no credited H₂ transport
No H₂ transport evidence — the filter has no H₂ transport properties (permeance, permeability, diffusivity, or transmission rate) and no FilterGasTransport records. The containment engine uses zero credited H₂ removal. Air Flow/ΔP data is never used as H₂ removal evidence.
Warnings: 4 warning(s).
Transport not calculated for N2: UNSUPPORTED_PROPERTY_DATA
Transport not calculated for O2: UNSUPPORTED_PROPERTY_DATA
Routed through canonical containment engine. Filter transport values originate from the filter's supported characterization — not from air ΔP.
Filter Design Evaluation
Insufficient Data
One or more required categories have insufficient data.
Warnings (7)
- Flow requirement not defined.
- Flow or ΔP requirement not defined.
- No particulate retention data. Requirement defined but no evidence available.
- Gas transport requirement not defined (TBD). No H₂ transport evidence.
- No loading data. Loading margin not evaluated.
- … and 2 more
Design Workflow
?Define filter geometryTBD
?Define engineering requirementsTBD
○Characterize flow / ΔPNOT EVALUATED
○Add particulate retention evidenceNOT EVALUATED
○Characterize H₂ / gas transportNOT EVALUATED
○Add loading evidenceNOT EVALUATED
○Add structural evidenceNOT EVALUATED
✓Evaluate against scenarioCOMPLETE
○Run design evaluationNOT EVALUATED
○Compare configurationsNOT EVALUATED
○Generate reportNOT EVALUATED